Skip to content
Home / Products / Ductless Range Hoods / Light-duty Series
Product Series

Light-duty Series

Ductless recirculating purifier with six filtration layers, honeycomb carbon and UV deodorising - no external duct, no wall coring.

Light-duty Series

Overview

The Light-duty Series (KL-D-N) is a ductless recirculating purifier developed for commercial sites that have no exhaust duct. Instead of an external flue, cooking fumes pass through a six-stage filtration train inside the cabinet – mechanical filtration, activated carbon and UV photolysis – and the cleaned air is returned to the room. Smoke and odour are handled in the same pass.

The range covers three body lengths – 1200 mm, 1600 mm and 2000 mm – all built with a stainless-steel housing, a touch-screen control panel and a 350 mm multi-blade silent impeller, running on a standard 220 V supply. It is built for mall islands, shop-in-shop units, B1 basement levels and other positions where a flue is not available, so a hot-food concept can open where it otherwise could not.

How the Purification Works

Six Filtration Layers, Nine Stages

From the cooking source to clean air, the airstream is treated layer by layer inside the cabinet: intercept first, filter next, deodorise last.

  1. Capture Zone: draws grease particles into the unit.
  2. Plume Gathering Zone: converges the airflow so it spreads evenly across the filter face.
  3. Metal Physical Interception: traps large grease and steam particles.
  4. Bubble Metal Filter Mesh: captures oil droplets of 5 microns and above.
  5. Medium-Efficiency Filtration: removes more than 95% of grease particulate.
  6. High-Efficiency Filtration Layer: removes 99% of particulate.
  7. Honeycomb Activated Carbon: columnar carbon adsorbs and locks in odour molecules.
  8. UV Photolysis: breaks down odour molecules and reduces VOCs.
  9. Centrifugal Fan: returns clean air to the room, completing the recirculation loop.

Bubble Metal Filter Mesh – Two Mechanisms

Physical interception: the porous metal structure forms a large number of micro channels; anything larger than the pore size is held on the mesh surface or inside the pores.

Adsorption: fine particles are held on the pore walls by intermolecular force (van der Waals force) and separated from the airstream.

The mesh can be removed, washed with water and reused, which keeps long-term consumable cost down.

350 mm Multi-Blade Silent Impeller

An aerodynamic profile draws air evenly, with strict dynamic and static balancing correction for high static pressure and stable running. Developed for harsh grease-exhaust duty, it is moisture-proof, oil-proof, heat-resistant and fully enclosed.

Touch-Screen Control Panel

The panel shows front and rear temperature, service life of filter cartridge I and II, time and remaining cleaning time, and controls six functions: fan, purifier, lighting, water pump, cleaning and water level. Nine-speed variable-frequency adjustment cuts energy use by more than 40% overall, and the control board supports RS-485, PLC interlocking, an IoT port and external remote control.

Key Features

  • Smoke and odour together, 99% or better: grease particulate and odour molecules are treated in the same pass, so the counter stays clear and the shop stays free of cooking smell.
  • Ductless recirculation – open without a flue: no external ducting, no wall coring and no damage to the fit-out; mall positions without a flue can go ahead directly.
  • Touch-screen control, nine speeds, over 40% energy saving: speed is matched to the actual smoke load, balancing purification against power use.
  • Quiet running for open counters: the 350 mm multi-blade impeller stays quiet at low speed, suited to open display counters.
  • 220 V mains supply, plug and run: no 380 V three-phase rewire – malls, food stalls and street shops can use it directly.
  • Stainless-steel body, modular maintenance: filter elements can be removed for washing or replacement, and the finish suits an open counter on display.

Application Scenarios

  • Mall Islands and Multi-Tenancy Points: open-format atrium and corridor positions with no exhaust route.
  • B1 Basement Units: basement-level food units where no external duct can be run.
  • Shop-in-shop Units: small food counters and light-meal zones inside supermarkets and mixed-use complexes.
  • Open Display Counters: front-of-house preparation counters and snack display areas.
  • Metro Retail Points: in-station food counters where recirculation keeps the public environment unaffected.
  • Convenience-Store Light-Meal Corners: steamed-bun holding and light-meal heating areas in convenience stores and coffee shops.

Suitable Food Formats

  • Oden and Holding Counters: simmered light-smoke formats served at a constant temperature.
  • Fresh-Cooked Marinated Dishes: cooked and served on the spot, with odour handled at the same time.
  • Takoyaki: light griddle frying, prepared in front of customers.
  • Pancakes and Hand-Pulled Pastry: gridded dough items, fast service and light smoke.
  • Steamed Buns and Dim Sum: steam heating with moisture handling.
  • Light-Meal and Mixed Counters: several formats combined, handled by one unit.

Problems It Solves

  • No flue at the site: mall islands, shop-in-shop units and B1 levels have no exhaust shaft, so hot-food concepts cannot open. Ductless internal recirculation lets the site open directly.
  • Smoke and odour complaints: fumes and smell escaping draw repeated complaints from neighbouring shops and customers. Six-stage purification with carbon and UV deodorising lowers that risk.
  • Property approval: without a fume-handling solution, mall management will not approve the fit-out. The unit is built to commercial kitchen fume-control requirements and can be submitted to property management as the fume-handling proposal for a ductless site.
  • Ductwork cost: laying ducts, coring external walls and installing fans is expensive and slow. This unit needs no modification and no coring – plug it in and run.
  • Poor working conditions at the counter: smoke filling the stall makes it unpleasant for staff and leaves the shop smelling. Fumes are purified on the spot, so open-counter work is not choking.
  • Menu and site limits: popular formats get ruled out by exhaust conditions. With one unit covering several formats, both menu and site choice open up.

Specifications

Parameter Value
Purification Efficiency ≥ 99%
Rated Power 600 – 1,200 W (model dependent)
Airflow 4,000 – 7,000 m³/h (model dependent)
Rated Voltage 220 V / 50 Hz
Fan Control Nine-speed variable frequency
Filtration Stages Metal interception, bubble metal mesh, medium and high-efficiency filtration, honeycomb carbon, UV photolysis
Body Material Stainless steel
Certification CE

Model Range

Model Dimensions (L×D×H) Efficiency Rated Power Voltage Weight Fan Speed Body
KL-D-N12 1200 × 800 × 850 mm ≥99% 600 W 220 V 110 kg 9-speed Stainless steel
KL-D-N16 1600 × 800 × 850 mm ≥99% 1,100 W 220 V 150 kg 9-speed Stainless steel
KL-D-N20 2000 × 800 × 850 mm ≥99% 1,200 W 220 V 200 kg 9-speed Stainless steel

Selection guide: KL-D-N12 suits small holding counters and oden stalls; KL-D-N16 suits takoyaki, pancake and fresh-cooked marinated counters as the main unit; KL-D-N20 suits mall islands and mixed-format open counters. Modular assembly and custom lengths are supported; the shipped configuration of each unit is final.

Reference Setups

The configurations below show how the range is typically matched to a site. Customer names and site details are anonymised.

  • B1 basement oden counter: KL-D-N12, installed in a basement unit with no flue; went through property review, with no noticeable cooking smell at the counter.
  • Shop-in-shop takoyaki counter: KL-D-N16, placed as an open display counter; the stainless-steel body matches the store fit-out.
  • Metro retail light-meal counter: KL-D-N20, running several formats together; indoor recirculation leaves the station’s public environment unaffected.
  • Convenience-store coffee and light-meal area: KL-D-N12, paired with steamed-bun and holding counters, with no external duct and no odour in store.
Certifications & Compliance

Built to Global Standards

Every SOUNINY unit is engineered, tested and supported by a verified commercial-kitchen air-purification manufacturer.

CE

CE Certified

Conforms to EU health, safety and environmental requirements for commercial equipment placed on the European market.

STD

Code Compliant

Designed to commercial-kitchen ventilation standards such as EN 16282 and referenced UL 710 / ASHRAE 154 practices for grease and smoke control.

MFG

Factory-Direct

Made by a National High-Tech Enterprise founded in 2015. Minimum order quantity of 1 unit, with full OEM / ODM customization.

SUP

Warranty & Support

12-month warranty, global shipping and English technical support from our application engineering team.

Manufactured by Shenzhen Shuangni Environmental Technology Co., Ltd. — learn more about our facilities and global projects on the About page.

FAQ

Frequently Asked Questions

Can this unit be used without an exhaust duct?
Yes. It is designed for internal recirculation - filtering and deodorising happen inside the cabinet and the cleaned air is returned to the room. No external ducting, no wall coring and no damage to the fit-out, so mall islands, shop-in-shop units and B1 basement levels with no flue can open directly.
How effective is the purification? Does it really remove odour?
Purification efficiency is 99% or better. Beyond grease particulate, the unit carries a honeycomb activated-carbon layer that adsorbs and locks in odour molecules, plus a UV stage that breaks down odour molecules and reduces VOCs - smoke and smell are handled together.
Is it noisy? Will it disturb an open counter?
It uses a 350 mm multi-blade silent impeller with nine-speed variable-frequency control, so it stays quiet at low speed - suited to open display counters and mall environments.
How do I choose a model? Which size suits which counter?
Choose by throughput and format: KL-D-N12 suits small holding counters and oden stalls; KL-D-N16 suits takoyaki, pancake and fresh-cooked marinated dishes as the main counter unit; KL-D-N20 suits mall islands and mixed-format open counters. Share your site details with our team and we will match the model to it.
Does the electrical supply need changing? Can an ordinary shop use it?
The whole range runs on 220 V / 50 Hz mains, with no need to rewire for 380 V three-phase. Mall units, food stalls and street shops can plug it in and run.
Does the filter mesh need frequent replacement? Is maintenance a hassle?
The bubble metal filter mesh can be removed, washed with water and reused. The carbon and high-efficiency layers are replaced on a cycle that depends on usage, and the panel shows cartridge life and remaining cleaning time, so service points are always visible.
Will mall property management approve it?
The unit is built to commercial kitchen fume-control requirements and can be submitted to property management as the fume-handling proposal for a ductless site. Entry requirements vary between malls, so it is best to submit the specification sheet for confirmation during the selection stage.
How do the light-duty and heavy-duty models differ?
The light-duty range (KL-D-N series) uses metal filtration with activated carbon and UV, suited to simmering, braising, light frying, steaming and baking. The heavy-duty range (KL-D-ND series) uses water spray, ionisation, HEPA and coconut-shell carbon, suited to deep frying and wok stir-frying. Choose the line that matches your menu.

Need Help Choosing?

Tell us your kitchen type, required airflow and target market — we'll recommend the right model and send a tailored quote.

Email: info@souniny.com
CHAT